PSP Armored Central Tube Optical Fiber Cable

PSP Armored Central Tube Optical Fiber Cable
  • PSP(Polyethylene-coated Steel Polymer) enhancing moisture-proof and rodent damage.
  • Gelly-filled, PBT loose tubes with optical fibers
  • Available from 6 to 24 fibers for seamless network expansion.
  • Supports G.652D, G.657A, and G.655C single-mode fibers to meet diverse bend-insensitivity demands.
  • Ensures ultra-low attenuation characteristics (≤0.36 dB/km at 1310 nm; ≤0.23 dB/km at 1550 nm) for long-distance transmission.
  • The cable has two phosphate steel wires with a diameter of 1.2 mm to improve tensile strength.
  • Provides versatile deployment options for duct, conduit, and aerial installations.
  • Low transmission attenuation and dispersion.
  • Delivers a future-proof, robust infrastructure solution for FTTH and outdoor fiber optic networks.


https://telexc.com/contact/

 

PSP Armored Optical Fiber Cable is designed for high-performance outdoor communications and FTTx networks. Constructed with a gel-filled central loose tube and two parallel phosphate steel wires for superior tensile strength, this PSP armored optical fiber cable offers maximum protection against moisture, mechanical stress, and rodent damage in duct and conduit installations.

PSP Armored Central Tube Optical Fiber Cable
General Specifications
Product type Central Tube PSP Armored Cable
Construction Type Armored
Fiber Coloring White
Jacket Marking Feet/Meter
Subunit Type Gel-filled
Total Fiber Count 6/12/24
Dimensions
Diameter Over Jacket 10.6 mm (0.417 in)
Mechanical Specifications
Max. Tensile Strength, Long-Term 600 N (135 lbf)
Max. Tensile Strength, Short-Term 1500 N (337 lbf)
Minimum Bend Radius, loaded 212.0 mm (8.346 in)
Minimum Bend Radius, unloaded 159.0 mm (6.260 in)
Compression 10 N/mm (57 lb/in)
Flex 30 cycles
Impact 0.74 N-m | 6.55 in lb
Twist 10 cycles
Optical Specifications
Fiber Type  G.652.D and G.657.A1
Attenuation, maximum 0.3 dB/km @ 1,550 nm | 0.4 dB/km @ 1,310 nm/1383 nm
Fiber Core Diameter 0,01in (250 µm)
Environmental Specifications
Installation temperature -5 °C to +55 °C (+23 °F to +131 °F)
Operating Temperature -20 °C to +70 °C (-4 °F to +158 °F)
Storage Temperature -20 °C to +70 °C (-4 °F to +158 °F)
Cable Qualification Standards ANSI/ICEA S-87-640 | IEEE-1222
Water penetration Sample length: 3m | Water head: 1m | Time: 24h
No leakage
Water Test: IEC 60794-1-22 Method F5
Environmental Test Specifications
Environmental Space Duct installation | Outdoor
Packaging and Weights
Cable weight 100 kg/km (67.197 lb/kft)

1. Aerial Installations

Power Lines: Installed along high-voltage power lines without risk of electromagnetic interference (EMI) or lightning strikes, as the all-dielectric design does not conduct electricity.

Telecommunications Towers: Connects aerial towers to deliver reliable data transmission over long distances.

2. Outdoor Backbone Networks

Long-Distance Communication: Forms the core of long-distance fiber networks across remote or rural regions due to strong environmental resistance and durability.

Inter-City Links: Connects neighboring cities to provide high-speed, uninterrupted communication for telecom operators and ISPs.

3. Rural & Harsh Environments

Rural Telecommunications: Ideal for aerial deployment where underground trenching is too costly or difficult due to terrain.

Extreme Weather Zones: Built to withstand high temperatures, extreme humidity, and intense UV exposure without degradation.

4. Transportation & Transit Systems

Rail Networks: Supports communication between railway stations and control centers without interference from high-voltage electrification systems.

Highway Monitoring: Powers roadside traffic monitoring, emergency communication points, and surveillance cameras.

5. Industrial & High-Risk Facilities

Factories & Plants: Ensures stable data transmission in factory environments heavy with electrical noise.

Oil & Gas Fields: Eliminates spark risks caused by metallic components in volatile or hazardous environments.

6. Urban Infrastructure

Smart Cities: Connects urban monitoring networks, traffic control systems, and public Wi-Fi infrastructure requiring fast, dependable connectivity.

Q1: Can this type of cable be buried directly in the ground?
A: Not without extra protection. Because these cables have no metal armour, they are vulnerable to crushing, rocks, and rodent bites. If you need to bury them, you must install them inside a conduit, pipe, or concrete duct to prevent damage.


Q2: Does the cable provide electrical grounding or lightning protection?
A: No. The all‑dielectric (non‑metallic) construction is excellent for avoiding electromagnetic interference, but it cannot be used for grounding. In places where you need a conductive path (e.g., for lightning down‑leads), you will have to choose a cable with metallic elements.


Q3: How strong is it against pulling forces?
A: It has moderate tensile strength, thanks to a central FRP (fibreglass) rod, but it is not as strong as steel‑reinforced or armoured cables. That means it is not suitable for long‑span aerial installations, underwater use, or any situation where high pulling stress is expected.


Q4: Is it resistant to rodents?
A: Not really. The plastic sheath offers little defence against rats or squirrels. In areas with heavy rodent activity, you should either place the cable in a rodent‑proof conduit or choose a cable that has a metal armour layer.


Q5: Can it withstand heavy pressure or impacts?
A: Its crush resistance is limited. Without a steel tape or wire armour, the cable can be easily damaged if run over by vehicles, struck by heavy tools, or pressed against sharp rocks. In industrial or construction zones, protective piping is highly recommended.


Q6: Is it safe to install in high‑traffic areas, such as along roads or busy footpaths?
A: Not if it is exposed. The cable is easily damaged by frequent foot or vehicle traffic. If installation is unavoidable in such places, you must put it inside a strong protective duct or a buried trough.


Q7: Does sunlight affect the outer sheath over time?
A: Yes. The polyethylene (PE) jacket has some UV resistance, but years of direct sunshine, especially in tropical or high‑altitude regions, will gradually make the sheath brittle and cracked. Regular inspections and, if possible, using a cable with enhanced weather‑resistant jacket are advisable.


Q8: Can it be used in rocky, abrasive, or harsh terrain?
A: Not ideally. The soft outer jacket is easily cut or abraded by sharp stones and rough surfaces. In such environments, a double‑armoured cable or a heavy‑duty outdoor cable is a much better choice.


Q9: How do extreme temperatures affect its performance?
A: Wide temperature swings can still cause the jacket to expand and contract, which may increase signal loss (micro‑bending). For areas with severe cold or heat, you should select a cable that is rated for that specific temperature range.


Q10: If the cable itself is inexpensive, why can the total project cost be higher?
A: While the cable is lightweight and cost‑effective for aerial use, the extra protection it needs (conduits, ducts, or special supports) for underground or high‑risk areas often adds significant material and labour costs. In the end, the total installation may become more expensive than using an armoured cable from the start.


Final Recommendation
This type of non‑metallic cable works best in aerial or duct‑based installations where mechanical stress is low. For direct burial, heavy traffic zones, rodent‑prone areas, or rocky ground, you should evaluate stronger armoured alternatives (e.g., steel‑tape or steel‑wire armoured cables) to ensure long‑term reliability.

Engineered for Reliability, Built for Trust

At Telexc, we don’t just supply hardware—we secure your global network deployment. Operating from China’s premier industrial clusters and the Tianjin logistics hub, we act as your private supply chain control tower, ensuring engineering precision and traceably consistent quality for every aerial installation.

Our Core Advantages

  • Full-Scenario Aerial Compatibility: We seamlessly bridge the gap between OSP fiber infrastructure, FTTH networks, and aerial deployment scenarios. Every component is structurally engineered to work harmoniously together, drastically increasing on-site installation efficiency.
  • Strict Engineering Standard Alignment: Our technical design loops strictly align with international benchmarks, including IEC, ITU-T, and IEEE standards. This ensures our hardware excels under extreme environmental stresses—from intense UV exposure to heavy wind and ice loads.
  • Independent Multi-Stage Quality Control: We act as your eyes on the ground. From raw material stress simulations to finished product compliance, our dedicated QC team performs rigorous multi-stage audits so you receive exactly what your engineers approved.
  • Optimized Logistics & Flexible Partnerships: Leveraging the logistics power of the Tianjin port, we guarantee reliable transit, competitive factory-direct structures, and transparent milestone tracking to keep your network projects moving forward without compromise.