| Stranded Loose Tube Optical Fiber Ribbon Cable | ||||||
| General Specifications | ||||||
| Cable Type | Stranded Loose Tube Optical Fiber Ribbon Cable | |||||
| Construction Type | Armored | |||||
| Subunit Type | Gel-filled | |||||
| Jacket Material | PE (Polyethylene) | |||||
| Jacket Marking | Feet/Meter | |||||
| Total Fiber Count | 144 | 192 | 216 | 288 | 432 | 576 |
| Dimensions | ||||||
| Diameter Over Jacket | 16.8 mm (0.661 in) | 17.4 mm (0.685 in) | 19.6 mm (0.772 in) | 18.5 mm (0.728 in) | 21.7 mm (0.854 in) | 22.3 mm (0.878 in) |
| Mechanical Specifications | ||||||
| Minimum Bend Radius, loaded | 336 mm (13.2 in) | 348 mm (13.7 in) | 392 mm (15.4 in) | 370 mm (14.5 in) | 434 mm (17.1 in) | 446 mm (17.5 in) |
| Minimum Bend Radius, unloaded | 168 mm (6.6 in) |
174 mm (6.8 in) |
196 mm (7.7 in) |
185 mm (7.2 in) |
217 mm (8.5 in) |
223 mm (8.7 in) |
| Tensile Load, Installation, maximum | 1000 N (225 lbf) | |||||
| Tensile Load, Operation, maximum | 300 N (67 lbf) | |||||
| Compression | 3 N/mm | 67 lbf / 3.937 in | |||||
| Flex | 25 cycles | |||||
| Impact | 4.5 N-m | 40 in-lb | |||||
| Twist | 10 cycles | |||||
| Optical Specifications | ||||||
| Fiber Type | G.652.D and G.657.A1 | |||||
| Attenuation, maximum | 0.3 dB/km @ 1,550 nm | 0.4 dB/km @ 1,310 nm/1383 nm | |||||
| Environmental Specifications | ||||||
| Installation temperature | -30 °C to 70 °C (-22 °F to 158 °F ) | |||||
| Operating Temperature | -40 °C to 70 °C (-40 °F to 158 °F ) | |||||
| Storage Temperature | -40 °C to 70 °C (-40 °F to 158 °F ) | |||||
| Water Penetration | Sample length: 3m | Water head: 1m | Time: 24h No leakage Water Test: IEC 60794-1-22 Method F5 |
|||||
| Environmental Test Specifications | ||||||
| Environmental Space | Duct installation | Outdoor | |||||
| Packaging and Weights | ||||||
| Cable weight | 246 kg/km (165.304 lb/kft) | 273 kg/km (183.448 lb/kft) | 328 kg/km (220.406 lb/kft) | 313 kg/km (210.326 lb/kft) | 418 kg/km (280.883 lb/kft) | 439 kg/km (294.994 lb/kft) |
- Mass fusion splicing for rapid deployment and time savings
- Armored with anti-moisture steel tape
- Gelly-filled, PBT loose tubes with optical fibers
- Higher fiber density, available from 144 to 864 fibers for seamless network expansion.
- Supports G.652D, G.657A, and G.655C single-mode fibers to meet diverse bend-insensitivity demands.
- Ensures ultra-low attenuation characteristics (≤0.36 dB/km at 1310 nm; ≤0.23 dB/km at 1550 nm) for long-distance transmission.
- Provides versatile deployment options for duct, conduit, and aerial installations.
- Delivers a future-proof, robust infrastructure solution for FTTH and outdoor fiber optic networks.