Hot-Dip Galvanized Immobility Clamp for Tower & Pole – Model TX-IC01

Key Features

  • Designed for tower and pole applications

  • High mechanical strength and load-bearing capacity

  • Hot-dip galvanized steel resists corrosion and UV exposure

  • Supports ADSS cable suspension and dead-end attachment

  • Easy installation without damaging the tower/pole structure

  • Available in straight, tension, and hoop types

  • Suitable for angle, terminal, and tangent towers

The TX-IC01 Immobility Clamp is a versatile hardware fitting designed to fix or connect ADSS cables and other telecom accessories on towers and poles. It comes in two main types: Tower Type with metal clamps for steel towers, and Pole Type with hoops for wooden, concrete, or metal poles.

This clamp ensures secure suspension points for cables without compromising the structural integrity of towers or poles. Made from hot-dip galvanized steel, the TX-IC01 offers high mechanical strength, corrosion resistance, and long-term durability in outdoor environments.

It is ideal for angle towers, terminal towers, tangent towers, or poles where ADSS cables need suspension or dead-end fixation. Easy to install and engineered for performance, the TX-IC01 is widely used in power, telecom, and fiber optic overhead line projects.

International Standard Compliance

  • ISO 9001 Quality Management Certification

  • Manufactured according to IEC telecom hardware standards

  • Corrosion resistance tested for outdoor use

  • Mechanical load testing for devastating loads as per industry standards

Construction & Materials

  • Body: Hot-dip galvanized steel, providing high tensile strength and long-term corrosion protection

  • Tower Clamp Type: Metal splint design for secure mounting on steel towers

  • Pole Clamp Type: Hoop design to attach preformed dead-end or suspension sets

  • Manufacturing Process: Steel forming, galvanization, welding (if required), and mechanical testing

Installation Guide

For Tower Type Clamp:

  1. Select the correct clamp size based on tower dimensions and cable diameter.

  2. Position the metal clamp on the tower leg or cross-arm.

  3. Secure the clamp using bolts or hardware compatible with the tower structure.

  4. Attach the ADSS cable or other accessories to the clamp.

  5. Ensure proper tensioning and alignment of cables.

For Pole Type Hoop Clamp:

  1. Select the hoop size corresponding to the pole diameter.

  2. Wrap the hoop around the pole.

  3. Attach preformed dead-end or suspension sets to the hoop.

  4. Confirm that the clamp is tightly fixed and cables are secured.

Hot-Dip Galvanized Immobility Clamp for Tower & Pole | Telexc
Hot-Dip Galvanized Immobility Clamp for Tower & Pole

Technical Parameters

Tower Type Immobility Clamp

Type

TX Code

Cable Fixing Dimension (mm)

Material

Devastating Load (kN)

 

 

 

 

 

Straight Clamp

TX-80/70

≤80

Galvanized Steel

70

TX-100/70

81–100

Galvanized Steel

70

TX-125/70

101–125

Galvanized Steel

70

TX-145/70

126–145

Galvanized Steel

70

TX-165/70

146–165

Galvanized Steel

70

TX-200/70

166–200

Galvanized Steel

70

 

 

 

Tension Clamp

TX-100/80

≤80

Galvanized Steel

100

TX-100/100

81–100

Galvanized Steel

100

TX-125/100

101–125

Galvanized Steel

100

TX-145/100

126–145

Galvanized Steel

100

TX-165/100

146–165

Galvanized Steel

100

TX-200/100

166–200

Galvanized Steel

100

Pole Type Hoop Clamp

Type TX Code Diameter of Fixing Locations (mm) Material Devastating Load (kN)
Hoop Clamp TX-125/70 101–125 Galvanized Steel 70
  TX-150/70 126–150 Galvanized Steel 70
  TX-175/70 151–175 Galvanized Steel 70
  TX-200/70 176–200 Galvanized Steel 70
  TX-225/70 201–225 Galvanized Steel 70
  TX-250/70 226–250 Galvanized Steel 70
  TX-275/70 251–275 Galvanized Steel 70
  TX-300/70 276–300 Galvanized Steel 70
  TX-325/70 301–325 Galvanized Steel 70
  TX-350/70 326–350 Galvanized Steel 70
  TX-375/70 351–375 Galvanized Steel 70
  TX-400/70 376–400 Galvanized Steel 70
  TX-425/70 401–425 Galvanized Steel 70
  TX-450/70 426–450 Galvanized Steel 70
  TX-475/70 451–475 Galvanized Steel 70
  TX-500/70 476–500 Galvanized Steel 70
  TX-525/70 501–525 Galvanized Steel 70
  TX-550/70 526–550 Galvanized Steel 70
  TX-575/70 551–575 Galvanized Steel 70
  TX-600/70 576–600 Galvanized Steel 70
  TX-625/70 601–625 Galvanized Steel 70
  TX-650/70 626–650 Galvanized Steel 70
  TX-675/70 651–675 Galvanized Steel 70
  TX-700/70 676–700 Galvanized Steel 70

 

Applications

  • Suspension point for ADSS cables on angle and terminal towers

  • Fixing of preformed dead-end and suspension sets on poles

  • Tangent towers and straight spans for overhead fiber optic cables

  • Power transmission and telecom infrastructure projects

  • Outdoor ADSS cable networks in harsh environments

Product Advantages

  • High load-bearing capacity for ADSS cables and accessories

  • Hot-dip galvanization ensures long service life and corrosion resistance

  • Available in multiple sizes for poles (125–700 mm) and tower clamps

  • Simplifies installation and reduces the risk of tower/pole damage

  • Compatible with a wide range of ADSS cable hardware

  • Lightweight, durable, and easy to handle in field operations

FAQs

1. What is an immobility clamp used for?
It fixes or connects ADSS cables and other fittings on towers or poles for secure suspension.

2. What types of immobility clamps are available?
Two main types: Tower Type (metal clamp) and Pole Type (hoop clamp).

3. What material is used for these clamps?
Hot-dip galvanized steel for high strength and corrosion resistance.

4. Can it be used outdoors?
Yes. Galvanized steel provides excellent durability in outdoor conditions.

5. What is the maximum load the clamps can handle?
Tower type tension clamps: up to 100 kN; Straight clamps: 70 kN; Hoop clamps: 70 kN.

6. How is the clamp installed?
Tower clamps use bolts or splints; pole clamps use hoop wrapping to secure preformed sets.

7. Are these clamps compatible with ADSS cables?
Yes. Designed specifically to support ADSS cables on towers and poles.

8. Can different sizes be ordered?
Yes. Multiple sizes are available for pole diameters 125–700 mm and tower cable locations 80–200 mm.

Why Choose Telexc

  • Certified quality manufacturing and ISO 9001 compliance

  • Customizable clamp types and sizes to match project requirements

  • Long-term durability with corrosion and UV-resistant materials

  • Wide experience in supplying telecom and power industry hardware

  • Cost-effective solutions with easy installation